Petrochemical Additives
locations:Home > Products > Petrochemical Additives
Corrosion Inhibitor for Acidizing
Release date: 2015-10-13 & Source: & Views: 1194
  • This product is used as corrosion inhibitor for acidizing fluid for oil and gas wells to protect the equipment and pipeline. It is suitable for hydrochloric acid, mud acid, emulsified acid, micellar acid and other kinds of acids up to 130 ℃, or 180 ℃ by blending with other additives.

     

    1.Typical physical properties /Technical data

    (1)Appearance: Red brown transparent liquid;

    (2)Density: (20℃) g/cm3:1.011.03;

    (3)Freezing point (℃) ≤-10;

    (4)Solubility: Soluble in water, saline and acid solution.

     

    2. Inhibition Performance

    Weight       HC1 Temperature Corrosion Rate       Test method
     %           %       ℃        g/m2.h  
     1.0          15      120        20
     2.0          28      120        40           SY5405-91
     2.0          20      130        40 

     

    3. Uses

    Add into water directly. Then add concentrated acid and blend well. It can also be added directly to dilute acid or concentrated acid and mix well. Dosage is 1.0 ~ 3.0% (V).

    Wear goggles and rubber gloves to avoid contact with face, hands and other parts of skin when using it. If splashing onto skin, rinse with plenty of water right away, and wash with soap.

     

    4. Shipping and storage

    (1)22kg/metal drum or at customers request.

    (2)Gently loading or unloading. Store in cool and well-ventilated place. Avoid fire source.

    (3)Shelf life 1 year.

      